The question from the client is
“Dear support, For cable stay bridges, please add the ability to check cable loss/replacement for multiple cable loss scenarios in one model.”
The client requestioned as:
“Dear support,
We do not use time history method as we believe this is too complicated and error-prone for this analysis. We use the static analysis method specified in PTI DC45.I where you run the model without the lost/replaced cable to quantify the effects on the rest of the structure. See the PTI extract adjacent to this cell. We have tried to do it using construction staging; a cable can be deactivated to run the analysis, but then you cannot simply reactivate that element, because the locked in forces in the structure will change. So subsequent cables cannot be checked in the same model.”
The here is “Boundary Change Assignment” option in midas civil.
Creating a strong and a weak link between cable and deck
Now, using “Change general link” option in midas civil which change the link property to weak link from strong link.
Then we define the “Boundary Change Assignment” under “Analysis” tab and will assign the “Change general link” property to the Nodal-load load case (CLDF).
Now we can observe in the second picture the additional cable forces due to cable snap.
Thank You!
Files | ||
---|---|---|
DataImage88.png
246 KB
|
||
DataImage10.png
211 KB
|
||
DataImage12.png
258 KB
|
||
DataImage46.png
411 KB
|
||
DataImage15.png
251 KB
|
||
DataImage2.png
380 KB
|
||
DataImage22.png
222 KB
|
||
DataImage7.png
169 KB
|
||
DataImage98.png
221 KB
|
||
DataImage1.png
206 KB
|
||
DataImage13.png
403 KB
|
||
DataImage87.png
326 KB
|
||
DataImage65.png
217 KB
|
||
DataImage85.png
236 KB
|
||
DataImage11.png
346 KB
|
||
DataImage54.png
271 KB
|
||
Cable loss-quasi static.mcb
215 KB
|
||
TH.avi
14 MB
|
||
DataImage99.png
1 MB
|
||
DataImage22.png
249 KB
|
||
DataImage91[1].png
192 KB
|
||
DataImage80.png
279 KB
|
||
DataImage50.png
446 KB
|
||
DataImage91.png
215 KB
|
||
DataImage61.png
415 KB
|
||
DataImage67.png
238 KB
|
||
DataImage72.png
176 KB
|
||
DataImage62.png
232 KB
|
||
DataImage51.png
220 KB
|
||
DataImage92.png
413 KB
|
||
DataImage81.png
350 KB
|
||
DataImage43[1].png
228 KB
|
||
DataImage57.png
195 KB
|
||
DataImage82.png
356 KB
|
||
DataImage73.png
281 KB
|
||
DataImage43.png
1 MB
|