Considering Suggested 9/12/2019 by Dylan Danks

1

votes

Load Rate Substructure

I was trying to do a load rating on a delta frame bridge and the program would only rate the superstructure. For most cases this is all that is needed. However, since the delta is a frame system meaning the superstructure and substructure are joined, the substructure had to be rated because it could control over the superstructure. I did the substructure rating by hand, but it would be nice if the program could handle rating it. 
AK
Angela Kim 9/12/2019 6:52 PM
Hi Dylan, can you please share your model file and drawing? If you do not wish to post it here, please kindly send it to angelakim@midasoft.com. Thanks!
AK
Angela Kim 9/12/2019 8:29 PM
Hi Dylan,

After the review of the model file, it looks like load rating of regular steel (non-composite section) will serve your needs, is it right?
DD
Dylan Danks 9/12/2019 8:37 PM
Yes load rating of regular steel non-composite would serve my needs.

Log in to comment...