I am running into an issue with Moving Load Tracer
I want to find coincident load effects with the maximum vertical reaction of Truck Load at Node 1288. When I look at the envelope the reaction is 583.2 kN
When I run the Moving Load Tracer it picks up the same maximum vertical load value:
However when I run the static loadcase created from the Moving Load Trace I get a different result and I can’t work out why:
I have attached the model file, if you could please advise what I need to do to get a static load case with consistent results and coinicident effects I would really appreciate it.
Files | ||
---|---|---|
DataImage3.png
935 KB
|
||
DataImage33.png
890 KB
|
||
DataImage79.png
946 KB
|
||
dnt_arch_3d_5.mcb