Creep & Shrinkage results are not available, even if time-dependent material properties are defined and linked.  Why?

Creation date: 9/24/2019 12:32 AM    Updated: 5/29/2023 10:43 AM   construction stage analysis control creep and shrinkage
Print...
Question:
Kindly refer to the image below.

Answer:

The time-dependent material properties are deactivated in the construction stage analysis control.  This needs to be active to view creep & shrinkage output.
DataImage71.png
model 2_pokus 1 destenový so ztužením_CSA_1 doska v jednom kroku.mcb
DataImage24.png

On this page